COMPARISON OF OPERATION OF KAUNAS AND KLAIPĖDA WWTPS DIGESTERS

Midona Dapkienė, Laima Česonienė, Tomas Pilipauskas

Abstract


The article provides comparison of operation of digesters for 2014, installed in wastewater treatment plants (WWTP) of two Lithuanian cities Kaunas and Klaipėda.  It was established that the temperature and decomposition degree of organic materials had impact on biogas discharge in digesters of both wastewater treatment plants. Increase of these technological parameters resulted in increase of biogas output. Actual output of biogas of Kaunas wastewater treatment plant digester was by 5.8 % less than theoretical output, in Klaipėda WWTP anaerobic reactor – by 4.2 %. After comparison of biogas discharge generated from 1 m3 of sludge in Kaunas and Klaipėda WWTPs it was established that the efficiency of Klaipėda WWTP digester exceeded the efficiency of Kaunas WWTP reactor by 7 %.

 Keywords: biogas, digester, decomposition degree of organic materials, temperature.

 Article DOI: http://doi.org/10.15544/RD.2015.042



Full Text:

PDF

Refbacks

  • There are currently no refbacks.